Why do Clamped Connections With Metallic Seals Sometimes Leak?

cover-pipe-clamp
Clamp connections with metallic seals can offer superior joint integrity over traditional flanged connections but caution must be exercised regarding the service conditions, especially when cyclic thermal loading is present. This blog post highlights aspects of a clamp connection analysis performed by Becht Engineering. The client had observed significant loss of bolt preload at several clamp connections installed in a refinery process unit where the fluid temperature regularly fluctuated by 700 o F. The client attempted to counteract the bolt preload loss by re-torqueing any bolts that showed a torque reduction from the initially applied torque only to find that, after a period during which thermal cycles occurred, the preload was again reduced. A typical clamp arrangement is seen in Figure 1 (with parts labeled). After reviewing the installation and service conditions, it was hypothesized that the cause of the bolt preload loss could be the differential thermal growth of the...
Continue reading
5
  575 Hits
  2 Comments
Recent Comments
Magnus Gustafsson

Re: Belleville Springs

Fran, No, we did not look at Belleville washers as part of this work. I do expect they would help, but I understand the preferred... Read More