Operability And Fitness-for-Service (FFS) Of ASME Equipment In Nuclear Power Plants

nuclear_plant
Bringing Order and Logic to the Evaluation Process There is a multitude of documents and reports that describe the damage mechanisms of ASME pressure equipment (vessels, pumps, valves, piping, and tanks, and their supports) in nuclear power plants. Thousands of pages published by EPRI, the NRC, ASME, NACE, research laboratories, utilities, contractors, and others, to read, study, and understand. The plant engineer must understand these thousands of pages of damage mechanisms, first to take the right preventive measures, and second, when the damage occurs despite our best efforts, to correctly diagnose the remaining life of the equipment, i.e. determine its fitness-for-service, its operability. In December 2018, EPRI published “Roadmap to Integrity Evaluation and Repair of Nuclear Plant Piping” EPRI report number 3002013156, to help the plant engineer navigate through the technical and regulatory complexities of damage mechanisms and the methods for the evaluation of remaining life. This is an important step...
Continue reading
2
  478 Hits
  0 Comments
478 Hits
0 Comments

Evaluation of Degraded and Nonconforming Conditions For ASME III and B31.1 and B31.7 Class 2 and Class 3 Pressure Boundary Nuclear Plant Components

Figure1-options_evaluating_wall-thinning
1.   Definitions 1.1    Degraded Condition A degraded condition as defined in NRC Inspection Manual 0326 Paragraph 03.02: “A degraded condition is one in which the qualification of an SSC or its functional capability is reduced. Examples of degraded conditions are failures, malfunctions, deficiencies, deviations, and defective material and equipment. Examples of conditions that can reduce the capability of a system are aging, erosion, corrosion, improper operation, and maintenance.” 1.2    Nonconforming Condition A nonconforming condition as defined in US NRC Inspection Manual 0326 Paragraph 03.06: “ A nonconforming condition is a condition of an SSC that involves a failure to meet the CLB or a situation in which quality has been reduced because of factors such as improper design, testing, construction, or modification. The following are examples of nonconforming conditions: An SSC fails to conform to one or more applicable codes or standards (e.g., the CFR, operating license, TSs, UFSAR, and/or licensee...