12 Checks When Qualifying Piping Systems in Nuclear Applications

becht_nuclear_12_checks
The analysis and qualification of piping systems in nuclear power plants involves more than meeting Code stress limits. Generally, a piping system is qualified if the following criteria have been met. These various qualification criteria are typically specified in the plant FSAR, the plant design procedures, or the ASME Code. Pressure design in accordance with the design Code. This check will govern the schedule of pipes, the thickness of tubing, the schedule and pressure class of fittings, the reinforcement of openings and branch connections, the pressure rating of valves, the pressure class of flanges, and the pressure design of specialty fittings. ASME Code stress limits . This check will verify that the Code stress equations for the load combinations corresponding to Test, Design, and Service Levels A, B, C, and D loadings have been met. NRC Standard Review Plan (SRP) Section 3.6 stress limits for the postulation of high energy...
Continue reading
6
  1151 Hits
  0 Comments
1151 Hits
0 Comments

Evolution of Pipe Stress Equations in the ASME Nuclear Codes (and where we are today)

piping_systems
The Pre-1955 Era Until 1955, the ASME Boiler and Pressure Vessel Codes, and the ASME B31 Pressure Piping code provided rules of good design practice with quantitative criteria for pressure design.  For example, quoting from ASME VIII Rules for the Construction of Unfired Pressure Vessels Section VIII A. S. M. E. Boiler Construction Code, 1927: U-20. For Internal Pressure. The maximum allowable working pressure on the shell of a pressure vessel shall be determined by the strength of the weakest course, computed from the thickness of the plate, the efficiency of the longitudinal joint, the inside diameter of the course, and the maximum allowable unit working stress.  (S×t×E)/R = maximum allowable working pressure Where S = maximum allowable unit working stress in lb. per sq. in. = 11,000 lb. per sq. in. for steel plate stamped 55,000 lb. per sq. in., 10,000 lb. per sq. in. for steel plate stamped...
Continue reading
3
  1622 Hits
  0 Comments
1622 Hits
0 Comments

Capacity Reduction of a Compression Member with an Initial Deformation

piping_support_3D
A recent review of equipment installed in a power plant found a piping strut that was visibly bent. Would the bend in the strut reduce its load bearing capacity as a compression member? The answer is YES!  The load bearing capacity of a bent strut against buckling is reduced. The reduction in buckling capacity is a function of the strut’s section properties and its initial deformation. We will see here how this can be quantified analytically (closed-form solution) and numerically (FEA solution). The equation for the maximum axial load capacity of a column, before it buckles, was first formulated by Leonhard Euler in 1757. F cr  = (π 2  E I)/(K L) 2 Where E = Young’s modulus of column material; I = cross-sectional moment of inertia of the column; L = unbraced length of column; and K is a factor that depends on the degree of fixity in the...
Continue reading
3
  786 Hits
  1 Comment
786 Hits
1 Comment

Evaluation of Corroded Pipe in Accordance with ASME B&PV Code Section XI - A Comparison of the Three Code Cases

Evaluation of Corroded Pipe in Accordance with ASME B&PV Code Section XI -
A Comparison of the Three Code Cases
The evaluation of wall thinning corrosion in steel pipes is addressed in three ASME XI code cases: N-513, N-597, and N-806. I have no ambition here other than to summarize in a table the differences between these three code cases. A brief commentary follows the table. The brief commentary... Line A – While these are Section XI Code Cases applicable to ASME III Class 2 and 3, technically, nothing would prevent from applying these Code Cases for B31.1 piping. Line B – There is no technical basis for limiting N-513 to moderate energy lines, i.e. pressure at or below 275 psi and (“or”, depending on the plant vintage) temperature at or below 200oF, other than the understandable reluctance to operate with hot water flashing to steam through a pinhole leak. Line D – It can be confusing that N-513 includes fracture mechanics consideration because it attempts to address cracks (so-called...
Continue reading
2
  1838 Hits
  0 Comments
1838 Hits
0 Comments